Thermo Scientific Gallery Plus 862 Discrete Analyzer | With PC/Soft

Description
MEASURING & ANALYSIS: Photometers
Thermo Scientific Gallery Plus Discrete Analyzer | With PC and Barcode Scanner
Automated discrete photometric analyzer, Type 862 without the ECM module, factory set up for water testing, sold with its PC workstation and Elo touchscreen running the Gallery Plus software, an Intermec SR30 barcode scanner, manuals and spare tubing, on 100-240 Vac.
Used Tested
At a glance
Manufacturer | Thermo Scientific
Model | Gallery Plus (Type 862)
Part / Catalog # | 98620001
Serial # | 862000110189
Year / DOM | 2015
Condition | Lightly Used, Excellent
What's Included
Thermo Scientific Gallery Plus discrete analyzer, Type 862
Desktop PC workstation with the Gallery Plus software
Elo touchscreen monitor
Keyboard and Logitech mouse
Intermec SR30 2D tethered barcode scanner, in box
Gallery Plus Operation Manual binder, revision 5.2A
Gallery Plus documentation binder
Dispensing probe (water), SP11253, in box
Pump tube 984077, bagged
Dispensing tube set N09591, diluent and wash tubes, bagged
Dispensing tube set N09592, drain and waste tubes, bagged
Tubing connector kit in box, as pictured
Box of numbered sample and reagent racks
Red transport locks
Sealed box of 10 mL reagent bottles, REF 984050
Nothing else is included unless shown in the photos
Condition Details
Analyzer powers on and communicates with the Gallery Plus software on the included workstation, which reports the system as Running; water and cuvettes were not loaded at the time of the photos; calibration verification is the responsibility of the buyer.
Specifications
Throughput Up to 350 tests/hour with a one-reagent method
Sample capacity Up to 108 samples in up to 6 racks of 9 or 18 positions
Sample volume 2 to 120 µL, extendable to 240 µL
Reagent positions 42, in a cooled disk
Reagent volume 2 to 240 µL
Reagent vials 10 mL and 20 mL
Sample containers 0.5, 2.0 and 4.0 mL cups and tubes
Cuvettes Disposable DECACELL cuvettes; 36 on board, 360 measurement cells
Reaction volume 120 to 300 µL
Photometer Single-channel interference filter photometer with reference beam splitter
Filters 12 filter positions, 340 to 880 nm
Light source Xenon flash lamp
Absorbance range 0 to 3.5 A
Resolution 0.001 A
Reproducibility SD under 0.005 A at 2 A
Incubation temperature 25 to 60 °C, no cooling, default 37 °C
Dispensing precision CV 2% or less for volumes of 2 µL and over
Barcode reading Code 128, Codabar, Interleaved 2 of 5 and Code 39 with check digit
LIS interface CLSI LIS02-A2 over RS-232 or TCP/IP
Water consumption 2.5 L/hour deionized water
Dimensions (W x D x H) 94 x 70 x 62 cm; 130 cm high with cover open
Weight 110 kg
Noise Under 60 dB(A) at 1 m
Operating environment 18 to 30 °C, 40 to 80% RH non-condensing
Use restriction Research use only, not for use in diagnostic procedures
Power 100-240 Vac, 50-60 Hz, 300 W. Verify voltage before purchase.
Specs from manufacturer literature for reference. Verify against your application.
Terms & Conditions
Payment
We accept most payment types and work with your organization's accounting requirements.
Contact us if you need a formal quote or to procure with a PO.
Shipping
Items ship within 1 to 2 business days after cleared payment.
We ship via USPS, FedEx, UPS, or freight, to the contiguous USA and worldwide.
Worldwide buyers are responsible for customs and duty import charges.
Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
You may arrange your own shipping through your own carrier on request.
Return Policy
60-day returns on all products from time of delivery.
If anything is not right, contact us first. We want you fully satisfied.
Why BioLabTek
We power on and function-test, then document what we saw
Photos show the exact unit you receive
Instruments packed to survive the carrier
POs and formal quotes welcome for academic and corporate buyers
Specifications
| Manufacturer | Thermo Scientific |
| Model | Gallery Plus (Type 862) |
| Year | 2015 |
| Condition | Used |
| Serial Number | 862000110189 |
| Stock Number | WPR1354 |
| Throughput | Up to 350 tests/hour with a one-reagent method |
| Sample capacity | Up to 108 samples in up to 6 racks of 9 or 18 positions |
| Sample volume | 2 to 120 µL, extendable to 240 µL |
| Reagent positions | 42, in a cooled disk |
| Reagent volume | 2 to 240 µL |
| Reagent vials | 10 mL and 20 mL |
| Sample containers | 0.5, 2.0 and 4.0 mL cups and tubes |
| Cuvettes | Disposable DECACELL cuvettes; 36 on board, 360 measurement cells |
| Reaction volume | 120 to 300 µL |
| Photometer | Single-channel interference filter photometer with reference beam splitter |
| Filters | 12 filter positions, 340 to 880 nm |
| Light source | Xenon flash lamp |
| Absorbance range | 0 to 3.5 A |
| Resolution | 0.001 A |
| Reproducibility | SD under 0.005 A at 2 A |
| Incubation temperature | 25 to 60 °C, no cooling, default 37 °C |
| Dispensing precision | CV 2% or less for volumes of 2 µL and over |
| Barcode reading | Code 128, Codabar, Interleaved 2 of 5 and Code 39 with check digit |
| LIS interface | CLSI LIS02-A2 over RS-232 or TCP/IP |
| Water consumption | 2.5 L/hour deionized water |
| Dimensions (W x D x H) | 94 x 70 x 62 cm; 130 cm high with cover open |
| Weight | 110 kg |
| Noise | Under 60 dB(A) at 1 m |
| Operating environment | 18 to 30 °C, 40 to 80% RH non-condensing |
| Use restriction | Research use only, not for use in diagnostic procedures |
| Power | 100-240 Vac, 50-60 Hz, 300 W |