Thermo Scientific Gallery 861 Discrete Analyzer | Automated Photometric Chemistry 2019

Price

$6,950 (USD)

Description

MEASURING & ANALYSIS: Photometers


Thermo Scientific Gallery Discrete Analyzer | Automated Photometric Chemistry

Automated discrete photometric analyzer, Type 861 without the ECM module, factory set up for food testing and running on 100-240 Vac; two units available, and the workstation PC and Gallery software are not included.


Used Tested


Manufacturer | Thermo Scientific

Model | Gallery (Type 861)

Part / Catalog # | 98610001

Serial # | 861000143021

Year / DOM | 2019

Condition | Lightly Used, Excellent


What's Included

Thermo Scientific Gallery discrete analyzer, Type 861

USB A to B interface cable

USB key labeled with the analyzer serial number, in the pouch inside the cover

Nothing else is included unless shown in the photos


Condition Details

Unit powers on and all functions tested normally; calibration verification is the responsibility of the buyer.


Specifications

Throughput Up to 200 tests/hour with a one-reagent method

Sample and reagent racks 9- or 18-position sample racks and 6-position reagent racks, up to 6 racks in the cooled disk

Sample volume 2 to 120 µL, extendable to 240 µL

Reagent volume 2 to 240 µL

Reagent vials 10 mL and 20 mL

Sample containers 0.5, 2.0 and 4.0 mL cups and sample tubes (12 to 16 mm diameter, 75 to 100 mm long)

Cuvettes Disposable DECACELL cuvettes; 36 cuvettes with 10 reaction cells, 360 measurement cells

Reaction volume 120 to 300 µL

Photometer Single-channel interference filter photometer with beam-splitting reference

Filters 12 filter positions, 340 to 880 nm

Light source Xenon flash lamp

Absorbance range 0 to 3.5 A

Resolution 0.001 A

Reproducibility SD under 0.005 A at 2 A

Incubation temperature 25 to 60 °C, no cooling, preset to 37 °C

Dispensing precision CV 2% or less for volumes of 2 µL and over

Barcode reading Code 128, USS Codabar, Interleaved 2 of 5 and Code 39 with check digit

LIS interface CLSI LIS02-A2 over RS-232 or TCP/IP

Water consumption 1.5 L/hour deionized water

Dimensions (W x D x H) 75 x 70 x 62 cm; 130 cm high with cover open

Weight 85 kg

Noise Under 60 dB(A) at 1 m

Operating environment 18 to 30 °C, 40 to 80% RH non-condensing

Use restriction Research use only, not for use in diagnostic procedures

Power 100-240 Vac, 50-60 Hz, 250 W. Verify voltage before purchase.

Specs from manufacturer literature for reference. Verify against your application.


Terms & Conditions


Payment

We accept most payment types and work with your organization's accounting requirements.

Contact us if you need a formal quote or to procure with a PO.


Shipping

Items ship within 1 to 2 business days after cleared payment.

We ship via USPS, FedEx, UPS, or freight, to the contiguous USA and worldwide.

Worldwide buyers are responsible for customs and duty import charges.

Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.

You may arrange your own shipping through your own carrier on request.


Return Policy

60-day returns on all products from time of delivery.

If anything is not right, contact us first. We want you fully satisfied.


Why BioLabTek

We power on and function-test, then document what we saw

Photos show the exact unit you receive

Instruments packed to survive the carrier

POs and formal quotes welcome for academic and corporate buyers

Specifications

ManufacturerThermo Scientific
ModelGallery (Type 861)
Year2019
ConditionUsed
Serial Number861000143021
Stock NumberWPR1353
ThroughputUp to 200 tests/hour with a one-reagent method
Sample and reagent racks9- or 18-position sample racks and 6-position reagent racks, up to 6 racks in the cooled disk
Sample volume2 to 120 µL, extendable to 240 µL
Reagent volume2 to 240 µL
Reagent vials10 mL and 20 mL
Sample containers0.5, 2.0 and 4.0 mL cups and sample tubes (12 to 16 mm diameter, 75 to 100 mm long)
CuvettesDisposable DECACELL cuvettes; 36 cuvettes with 10 reaction cells, 360 measurement cells
Reaction volume120 to 300 µL
PhotometerSingle-channel interference filter photometer with beam-splitting reference
Filters12 filter positions, 340 to 880 nm
Light sourceXenon flash lamp
Absorbance range0 to 3.5 A
Resolution0.001 A
ReproducibilitySD under 0.005 A at 2 A
Incubation temperature25 to 60 °C, no cooling, preset to 37 °C
Dispensing precisionCV 2% or less for volumes of 2 µL and over
Barcode readingCode 128, USS Codabar, Interleaved 2 of 5 and Code 39 with check digit
LIS interfaceCLSI LIS02-A2 over RS-232 or TCP/IP
Water consumption1.5 L/hour deionized water
Dimensions (W x D x H)75 x 70 x 62 cm; 130 cm high with cover open
Weight85 kg
NoiseUnder 60 dB(A) at 1 m
Operating environment18 to 30 °C, 40 to 80% RH non-condensing
Use restrictionResearch use only, not for use in diagnostic procedures
Power100-240 Vac, 50-60 Hz, 250 W