Agilent BioTek Synergy LX Touch Multimode Microplate Reader w/PC Gen5 Lum

Description
MEASURING & ANALYSIS: Microplate Readers
Agilent BioTek Synergy LX Multimode Microplate Reader | Touchscreen with Laptop
Absorbance, fluorescence and luminescence microplate reader with touchscreen, fitted with the luminescence filter cube and supplied with a Dell laptop running Gen5, on a 24 VDC external supply, passing its on-board system test.
Used Tested
At a glance
Manufacturer | BioTek / Agilent
Model | Synergy LX SLXFATS
Part / Catalog # | SLXFATS-SN
Serial # | 23051526
Year / DOM | May 15, 2023
Condition | Lightly Used, Excellent
What's Included
Agilent BioTek Synergy LX multimode reader with touchscreen
BioTek Lum filter cube (installed)
Dell laptop with Agilent BioTek Gen5 3.14 software installed
USB cable
Nothing else is included unless shown in the photos
Condition Details
Unit powers on and passed its on-board System Test, connects to Gen5 with status Ready and completed a luminescence plate read during testing; exterior is clean; calibration verification is the responsibility of the buyer.
Specifications
Detection modes UV-Vis absorbance, fluorescence intensity, luminescence
Read methods End point onboard; end point, kinetic, area scanning and absorbance spectral scanning under Gen5 control
Absorbance optics Xenon flash lamp, monochromator, photodiode detector
Absorbance wavelength range 200 to 999 nm in 1 nm increments
Absorbance bandwidth ≤ 5 nm
OD range 0 to 4.000 OD
OD resolution 0.001 OD onboard; 0.0001 OD under Gen5 control
Pathlength correction Yes
Wavelength accuracy ±2 nm
Wavelength repeatability ±0.2 nm (SD)
OD accuracy < 1% at 2.0 OD; < 3% at 2.5 OD
OD linearity < 1% from 0 to 2.5 OD
OD repeatability < 0.5% at 2.0 OD
Stray light 0.03% at 230 nm
Absorbance read speed 12 s for 96 wells; 23 s for 384 wells (kinetic)
Fluorescence optics Halogen lamp, filter cubes, PMT detector
Fluorescence sensitivity Fluorescein 2 pM
Fluorescence dynamic range > 6 decades
Fluorescence read speed 24 s for 96 wells; 76 s for 384 wells (kinetic)
Luminescence sensitivity 10 amol ATP
Luminescence dynamic range > 6 decades
Plate formats 6- to 384-well plates under Gen5 control; 96- and 384-well for fluorescence and luminescence onboard
Shaking Linear, orbital and double orbital
Interfaces 1 USB 2.0 port for computer control; 2 USB 2.0 ports for printer and flash drive
Dimensions (H x W x D) 38.1 x 38.1 x 38.1 cm with touchscreen
Weight ≤ 12.3 kg (27 lb)
Power 24 VDC, 60 W (external power supply 100-240 VAC, 50-60 Hz). Verify voltage before purchase.
Specs from manufacturer literature for reference. Verify against your application.
Terms & Conditions
Payment
We accept most payment types and work with your organization's accounting requirements.
Contact us if you need a formal quote or to procure with a PO.
Shipping
Items ship within 1 to 2 business days after cleared payment.
We ship via USPS, FedEx, UPS, or freight, to the contiguous USA and worldwide.
Worldwide buyers are responsible for customs and duty import charges.
Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
You may arrange your own shipping through your own carrier on request.
Return Policy
60-day returns on all products from time of delivery.
If anything is not right, contact us first. We want you fully satisfied.
Why BioLabTek
We power on and function-test, then document what we saw
Photos show the exact unit you receive
Instruments packed to survive the carrier
POs and formal quotes welcome for academic and corporate buyers
Specifications
| Manufacturer | BioTek / Agilent |
| Model | Synergy LX SLXFATS |
| Year | 2023 |
| Condition | Used |
| Serial Number | 23051526 |
| Stock Number | WPR1341 |
| Detection modes | UV-Vis absorbance, fluorescence intensity, luminescence |
| Read methods | End point onboard; end point, kinetic, area scanning and absorbance spectral scanning under Gen5 control |
| Absorbance optics | Xenon flash lamp, monochromator, photodiode detector |
| Absorbance wavelength range | 200 to 999 nm in 1 nm increments |
| Absorbance bandwidth | ≤ 5 nm |
| OD range | 0 to 4.000 OD |
| OD resolution | 0.001 OD onboard; 0.0001 OD under Gen5 control |
| Pathlength correction | Yes |
| Wavelength accuracy | ±2 nm |
| Wavelength repeatability | ±0.2 nm (SD) |
| OD accuracy | < 1% at 2.0 OD; < 3% at 2.5 OD |
| OD linearity | < 1% from 0 to 2.5 OD |
| OD repeatability | < 0.5% at 2.0 OD |
| Stray light | 0.03% at 230 nm |
| Absorbance read speed | 12 s for 96 wells; 23 s for 384 wells (kinetic) |
| Fluorescence optics | Halogen lamp, filter cubes, PMT detector |
| Fluorescence sensitivity | Fluorescein 2 pM |
| Fluorescence dynamic range | > 6 decades |
| Fluorescence read speed | 24 s for 96 wells; 76 s for 384 wells (kinetic) |
| Luminescence sensitivity | 10 amol ATP |
| Luminescence dynamic range | > 6 decades |
| Plate formats | 6- to 384-well plates under Gen5 control; 96- and 384-well for fluorescence and luminescence onboard |
| Shaking | Linear, orbital and double orbital |
| Interfaces | 1 USB 2.0 port for computer control; 2 USB 2.0 ports for printer and flash drive |
| Dimensions (H x W x D) | 38.1 x 38.1 x 38.1 cm with touchscreen |
| Weight | ≤ 12.3 kg (27 lb) |
| Power | 24 VDC, 60 W (external power supply 100-240 VAC, 50-60 Hz) |