Harvard Apparatus PHD ULTRA Programmable Syringe Pump | Standard Rack

Description
LIQUID HANDLING: Liquid Pumps
Harvard Apparatus PHD ULTRA Programmable Syringe Pump | Standard Rack
Used Harvard Apparatus PHD ULTRA infuse and withdraw programmable syringe pump with the standard syringe rack and color touchscreen, running on 100-240 V single phase and tested with an infusion run.
Used Tested
At a glance
Manufacturer | Harvard Apparatus
Model | PHD ULTRA
Part / Catalog # | 70-3007
Serial # | D-403360
Year / DOM | 2019
Condition | Lightly Used, Excellent
What's Included
Harvard Apparatus PHD ULTRA syringe pump, catalog 70-3007
Standard syringe rack with barrel clamp and pusher block
Power cord
Nothing else is included unless shown in the photos
Condition Details
Unit powers on, loads the Quick Start screen and ran an infusion at 3 mL/hr against a 10 mL syringe profile during testing; the exterior is clean; flow calibration verification is the responsibility of the buyer.
Specifications
Pump type Infuse and withdraw programmable syringe pump
Rack style Standard syringe rack
Control Color touchscreen with on-board method programming
Method storage On-board method steps stored in instrument memory
Syringe setup Syringe library with manufacturer, volume and barrel diameter entry
Force control Adjustable force limit set as a percentage
Communication RS-232, RS-485 in and out, USB, digital I/O
Other connections Foot switch input
Use restriction Research use only, not for clinical use on patients
Syringe size range 0.5 µL to 140 mL
Flow rate range 1.56 pL/min to 216 mL/min (0.5 µL to 140 mL syringes)
Accuracy ±0.25%
Reproducibility ±0.05%
Maximum linear force 75 lb at 100% force selection
Pusher travel rate 0.18 µm/min to 190.8 mm/min
Dimensions 30.5 x 21.6 x 18.4 cm (12 x 8.5 x 7.25 in)
Weight 4.5 kg (10 lb)
Operating temperature 4 to 40 °C (40 to 104 °F)
Power 100-240 V, 50/60 Hz, 0.5 A. Verify voltage before purchase.
Specs from manufacturer literature for reference. Verify against your application.
Terms & Conditions
Payment
We accept most payment types and work with your organization's accounting requirements.
Contact us if you need a formal quote or to procure with a PO.
Shipping
Items ship within 1 to 2 business days after cleared payment.
We ship via USPS, FedEx, UPS, or freight, to the contiguous USA and worldwide.
Worldwide buyers are responsible for customs and duty import charges.
Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
You may arrange your own shipping through your own carrier on request.
Return Policy
60-day returns on all products from time of delivery.
If anything is not right, contact us first. We want you fully satisfied.
Why BioLabTek
We power on and function-test, then document what we saw
Photos show the exact unit you receive
Instruments packed to survive the carrier
POs and formal quotes welcome for academic and corporate buyers
FDA MEDICAL DEVICE DISCLAIMER
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Specifications
| Manufacturer | Harvard Apparatus |
| Model | PHD ULTRA |
| Year | 2019 |
| Condition | Used |
| Serial Number | D-403360 |
| Stock Number | WPR1320 |
| Pump type | Infuse and withdraw programmable syringe pump |
| Control | Color touchscreen with on-board method programming |
| Method storage | On-board method steps stored in instrument memory |
| Syringe setup | Syringe library with manufacturer, volume and barrel diameter entry |
| Force control | Adjustable force limit set as a percentage |
| Communication | RS-232, RS-485 in and out, USB, digital I/O |
| Other connections | Foot switch input |
| Use restriction | Research use only, not for clinical use on patients |
| Syringe size range | 0.5 µL to 140 mL |
| Flow rate range | 1.56 pL/min to 216 mL/min (0.5 µL to 140 mL syringes) |
| Accuracy | ±0.25% |
| Reproducibility | ±0.05% |
| Maximum linear force | 75 lb at 100% force selection |
| Pusher travel rate | 0.18 µm/min to 190.8 mm/min |
| Dimensions | 30.5 x 21.6 x 18.4 cm (12 x 8.5 x 7.25 in) |
| Weight | 4.5 kg (10 lb) |
| Operating temperature | 4 to 40 °C (40 to 104 °F) |
| Power | 100-240 V, 50/60 Hz, 0.5 A |