GE Cytiva AKTA Pure 25M FPLC Chromatography System + Frac/PC 2017

Price

$29,500 (USD)

Description

SEPARATION GE Cytiva AKTA pure 25 M Chromatography System | Protein Purification Modular benchtop FPLC chromatography system for fast purification of proteins, peptides, and nucleic acids at laboratory scale. QC PASS Tested & Working At a glance Manufacturer GE Healthcare / Cytiva Model ÄKTA pure 25 M Fraction Collector F9-C Part / Catalog # 29018226 29015408 Serial # 2208444 2200996 Year / DOM 2017 Condition Used - Excellent What's Included GE Cytiva ÄKTA pure 25 M chromatography system Fraction Collector F9-C Dell desktop computer with Unicorn 7.6 software Power cords, Ethernet cable UniNet-9 control cable Nothing else is included unless shown in the photos Condition & Testing Unit powers on and UNICORN software loads to a Ready state with both system pumps, all valves, and the U9-M UV monitor recognized; no cracks or damage; flow-path calibration and performance qualification are the responsibility of the buyer. Specifications Specs from manufacturer literature for reference.

Specifications

ManufacturerGE Healthcare / Cytiva
ModelF9-C flexible fraction collector
ConditionUsed
Serial Number2200996
Mpn29018226 , 29014834 , 29027743
System typeLaboratory-scale FPLC / liquid chromatography purification system
Configured modulesV9-Inj, V9-IAB, V9-M, V9-L, V9-C, V9-pH, V9-O, U9-M, C9, L9, F9-C, P9 A, P9 B, R9, M9
System pumpsTwo high-performance pumps (P9 A and P9 B), one pair of pump heads each
Flow rate range0.001–25 mL/min (normal); up to 50 mL/min for column packing
Max operating pressure200 bar (2900 psi, 20 MPa)
Uv monitorU9-M multi-wavelength; 190–700 nm, up to 3 wavelengths simultaneously
Uv flow cell path lengths0.5, 2 (included at delivery), and 10 mm
Uv lampHigh-intensity xenon lamp; typical operating time ~5000 h; auto-calibrated at power-on
Conductivity monitorC9 (in-line, for gradient verification)
System pressure monitorR9 (continuous; auto-adjusts flow to avoid pressure limits)
MixerM9; 1.4 mL chamber included (optional 0.6 and 5 mL); in-line filter mounted inside
Injection valveV9-Inj; supports sample loops, Superloops, and direct-to-column application
Sample loop500 µL delivered with system
Inlet valveV9-IAB (selection between two A and two B positions)
Column valveV9-C (built-in bypass and reverse-flow functionality)
Ph valveV9-pH (in-line pH monitoring, calibration, and storage)
Outlet valveV9-O
External air sensorL9 (column protection)
Chromatography techniquesAffinity, size exclusion (SEC), ion exchange, hydrophobic interaction, and reversed phase (RPC)
Wetted materialsBiocompatible; resistant to commonly used solvents
Power input100–240 VAC, 50/60 Hz
Power consumption1100 VA (max)
Mains fuseT10AL250V
Mains outAs mains in (2 A max)
CommunicationUniNet-9 instrument interface; Ethernet (IP 10.1.1.1)
Ingress protectionIP21
Weight48 kg basic configuration; 53 kg fully equipped
Code no.29015408
Year / dom2017/02
Collection formatDeep-well plates and/or tubes
Outlet positions10 outlet positions + waste
Voltage32 V via UniNet-9 interface
Power18 VA max